Customization: | Available |
---|---|
Type: | Male Cylinder Connector |
Customized Support: | OEM,ODM |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Advantages
Material: 316 Stainless Steel |
Corrosion Resistance: Type 316 stainless steel offers superior resistance to corrosion, especially in aggressive chemical environments. |
Reliable Connection |
Male Thread Design: Ensures a secure, leak-tight seal by utilizing ferrules that grip the tubing both radially and axially. High Pressure Resistance: Capable of withstanding working pressures up to 3500 psi. |
Good Sealing and Repeatability |
Optimum Performance: The NPT thread design provides excellent sealing properties, ensuring consistent performance over multiple assembly cycles. Repeatability: Can be disassembled and reassembled multiple times without compromising the integrity of the connection. |
Commonly used CGA series models and relative to applicable gases |
CGA320:Fittings for gases such as liquaefied petroleum gas(LPG) and carbon dioxide(CO2). CGA580:Couplings for high pressure gases such as argon, helium, hydrogen, nitrogen and oxygen. CGA590:Couplings for nitrogen. CGA660:Couplings for gases such as ammonia and sulfur dioxide. CGA870:Couplings for medical oxygen. |
Surface Finish |
Ra Value: Typically finished to meet high-purity standards, BA-grade often with an Ra value of 10 μin or better. Electropolishing(EP-grade): Optional electropolishing for enhanced corrosion resistance and smooth surface finish. |
Convenient Installation and Maintenance | Easy to Install: Simple compression fitting design allows for quick and straightforward installation without the need for special tools. Maintenance-Friendly: Easy to inspect, maintain, and replace components as needed. |
Dimensions | Pipe Sizes: Available in metric sizes imperial sizes (1/8 inch, 1/4 inch, 3/8 inch, 1/2 inch, 3/4 inch,1inch,2~25mm) Head Code: Hexagon head for easy gripping and tightening. |
Safety |
CGA series cylinder couplings utilize well-designed valves and connection mechanisms to ensure the safe use and transmission of gases. |
Applicable gases: The CGA series cylinder couplings cater to an extensive spectrum of gases, tailored to the coupling type. Commonly embraced gases include:
Oxygen, Nitrogen, Argon, Hydrogen, Carbon Dioxide (CO2), Liquefied Petroleum Gas (LPG), Ammonia, and Sulfur Dioxide.
CGA series couplings are applicable fields
Industrial: The CGA series couplings serve an essential role in the industrial sector, adeptly connecting gas source equipment, gas storage, and transportation systems. Medical: These couplings are pivotal in the medical field, facilitating the connection of medical gases such as oxygen, nitrogen, and sevoflurane. Laboratory: Laboratories rely on CGA series couplings for connecting gas equipment and bottled gases.
Installation Guidelines
1. Preparation:
Ensure all surfaces are spotless and devoid of contaminants.
Confirm that the dimensions and specifications are precisely aligned with the intended application.
2. Alignment:
Precisely align the fitting with the connecting pipes to guarantee optimal compression.
Employ alignment tools if necessary to maintain impeccable accuracy.
3. Assembly:
Firmly insert the tubing into the fitting until it meets the shoulder inside the fitting body.
Tighten the elbow using a wrench, adhering to the manufacturer's recommended torque specifications.
4. Post-Installation Inspection:
Conduct a leak check by applying soapy water or a comparable solution around the joints.
Execute pressure tests to verify that the system is entirely leak-free.
Maintenance Tips
Regular Inspection:
Routinely inspect the fittings and surrounding areas for any indications of wear, corrosion, or leaks.
Examine threads for any deformation or damage.
Cleaning:
Select cleaning agents that are compatible and do not compromise the stainless steel surface.
Maintain pristine cleanliness to prevent contamination and uphold high-purity standards.
Packaging and Delivery
Selling Units: Single Item
Single Package Size: 13 x 10 x 7.5 cm
Single Gross Weight: 0.15 kg
Founded in 2011, Hunan Wofly Technology Co., Limited leads the charge in high-purity fluid control solutions. Our specialization spans valves and components, offering integrated gas distribution systems with ISO 9001 certification. Our portfolio, including diaphragm valves, precision instrumentation valves, and pressure regulators, complies with CE, RoHS, and SEMI S2 standards. Tailored for critical applications in semiconductor manufacturing, hydrogen energy, and photovoltaics, our solutions assure unmatched leak-tight performance in ultra-clean environments. With over a decade of dedication to elevating gas handling safety, Wofly stands as a beacon of certified reliability through rigorous quality control, empowering clients globally in mission-critical sectors.
Q1: What are the sizes and models of CGA fittings?
A1: CGA series fittings are available in a variety of sizes and models, common ones include CGA 326, CGA 330CGA 350,,CGA 510, CGA 540, CGA 580, CGA 590, CGA 660 and CGA 870. Each model is suitable for different gases and applications.
Q2: Which gases are CGA couplings suitable for?
A2: CGA couplings are suitable for a wide range of gases, such as oxygen, nitrogen, argon, helium, acetylene, ammonia and so on. The specific gases for which they are suitable depend on the type and standard of the coupling.
Q3: What are the advantages of CGA couplings?
A3: The advantages of CGA couplings include high quality and reliability, standardized interfaces to ensure interchangeability, safety, durability and long life. They are subjected to rigorous quality control and testing and are suitable for a wide range of gas system connection needs.
Q4: In which fields are CGA fittings often used?
A4: CGA fittings are widely used in a number of fields, including industrial and manufacturing industries, medical fields, laboratories and scientific research, and the food and beverage industry. They are used to connect gas cylinders and equipment for gas transmission and supply.
Q5: How to choose the right CGA connector?
A5:Choosing the right CGA connector requires consideration of the gas type, working pressure, application requirements and other factors. It is recommended to refer to relevant standards and guidelines and ensure that you speak to your supplier to ensure that you select the right fitting for your specific needs.
Q6: How to use and install CGA fittings safely?
A6: Safe use and installation of CGA fittings requires following relevant safety procedures and guidelines. Ensure that fittings are connected correctly, check for tightness, follow the correct pressure limits and operating procedures, and carry out regular inspections and maintenance.