Customization: | Available |
---|---|
Media: | Gas |
Temperature: | Low Temperature |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Features
Metal to metal seal provides leak-free service in vacuumto high pressure range
Small internal volume, can completely purge the flowpath
Fully wrapped seat design, with superior anti-expansionand anti-pollution capabilities
Nickel-cobalt alloy diaphragm for higher durabilityand corrosion resistance
The standard roughness is Ra0.25um(BA class)orelectrolytically polished Ra0.13um(EP class)
Helium test leakage rate <1x10-9mbar.l/sPneumatic executor s are available, Pneumatic valve lifeup to 3 million times
AUTOMATIC WELDING OF LONG PIPE | |||||
Basic Ordering Number | Connector types and specification | A (in. (mm)) | B (in. (mm)) | C (in. (mm)) | L (in. (mm)) |
WV4 - 6L - TW4 | 1/4" Tubebuttweld | 0.44(11.2) | 0.53(13.6) | 1.06(26.9) | 2.13(54.0) |
WV4 - 6L - TW6 | 3/8" Tubebuttweld | 0.44(11.2) | 0.83(21.1) | 1.06(26.9) | 2.72(69.0) |
WV4 - 6L - FR4 | 1/4" Female VCR connector | 0.44(11.2) | 0.86(21.8) | 1.06(26.9) | 2.78(70.6) |
WV4 - 6L - MR4 | 1/4" Integral male VCR connector | 0.44(11.2) | 0.62(15.7) | 1.06(26.9) | 2.24(57.0) |
WV4 - 6L - TF4 | 1/4" Female connector | 0.44(11.2) | 0.71(18.0) | 1.06(26.9) | 2.47(62.8) |
AFQ
Q:what is the working principle of pneumatic diaphragm valve?
A: Pneumatic diaphragm valve is driven by compressed air to pneumatic actuator, the movement of the actuator is transmitted to the diaphragm through the connecting parts. The diaphragm moves upward or downward under the action of air pressure, thus opening or closing the valve passage. When the diaphragm leaves the valve seat, fluid can pass through the valve; when the diaphragm is pressed against the valve seat, the valve closes, preventing fluid flow. The diaphragm of this type of valve separates the fluid from the actuator, effectively preventing fluid leakage to the actuator side.
Q:What are the main components of a pheumatic diaphragm valve?
A: It mainly consists of valve body, diaphragm, bonnet, pneumatic actuator (e.g. cylinder, piston, etc.), valve stem and connecting parts. The valve body is the main part of the fluid passage, the diaphragm is used to isolate the fluid and the actuator and control the fluid on and off, the bonnet is used to fix the diaphragm and connect the actuator, the pneumatic actuator provides the power to drive the diaphragm action, and the valve stem transmits the power from the actuator to the diaphragm.
Q:What are the precautions for installation of pneumatic diaphram valves?
A: The installation location should be easy to operate and maintain, and there should be enough space around. The valve should be installed vertically, so as to ensure that the diaphragm works properly under gravity, and avoid situations such as uneven force on the diaphragm due to tilting. During installation, attention should be paid to the connection between the pipeline and the valve to ensure a tight connection and prevent leakage. At the same time, the valve should be installed correctly in accordance with the flow direction of the piping system, and the direction of the arrow should be consistent with the direction of fluid flow.
Q:what checks need to be made on the valve before installation?
A: Before installation, check whether the model and specification of the valve meet the requirements, including calibre and pressure level. Check whether the diaphragm is intact, without cracks or perforations. Also check whether the action of the pneumatic actuator is flexible, there is no stagnation phenomenon, check whether the seals of the connection parts are complete and in good condition.
Q:How to control the opening of pneumatic diaphragm valve?
A: The valve opening can be controlled by adjusting the air pressure signal of the pneumatic actuator. In the automatic control system, according to the process requirements to set the control signal (such as 4 - 20mA current signal or 3 - 15 psi air pressure signal, etc.) and the valve opening the corresponding relationship, the controller output signal to drive the pneumatic actuator, so that the valve to achieve the desired opening. The valve opening can also be changed by manual adjustment device (if available). Q: What is the operating pressure range of pneumatic diaphragm valves? A: Different models and specifications of pneumatic diaphragm valves have different operating pressure ranges, generally their operating pressure ranges from vacuum to several megapascals. In use, according to the valve's nameplate identification and product specifications to determine its allowable operating pressure range, can not exceed this range, otherwise it may lead to valve damage or leakage.
Q:how do I perform routine maintenance on pneumatic diaphragm valves?
A: Periodically check the integrity of the diaphragm for signs of deterioration, wear or damage. Check the pneumatic actuator's air source connection for leakage, and clean the valve surface and actuator regularly to prevent dust and impurities from entering. Also check the valve connections for looseness and lubricate the moving parts of the pneumatic actuator regularly (if required).
Q:what are the common filures of pneumatic diaphragm valves? how to troubleshoot?
A: Common failures include diaphragm rupture resulting in leakage,
at which point the diaphragm needs to be replaced. If the pneumatic actuator moves slowly or does not move, it may be due to insufficient air pressure, clogged air tubes, or damage to internal parts of the actuator, which requires checking the air pressure, cleaning the air tubes, or repairing the actuator. There is also the case of internal leakage of the valve, may be between the diaphragm and the seat of the foreign body or diaphragm damage, need to clean up the foreign body or replace the diaphragm to solve the problem.
Wofly Technology was founded in2011 and is headquartered in Shenzhen, China.Hunan Wofly Technology Company Limited located in White Heron Information Industrial Park, Comprehensive Bonded Zone, Chenzhou Area, Pilot Free Trade Zone, China (Hunan) . Wofly Technology is a high-end technology-based enterprise integrating product development, production, sales, and gas system engineering planning, design, installation, and technical services, and has been awarded as a national high-tech enterprise, "SRDI"enterprises. Wofly specializes in the research, development and manufacture of high-purity fluid control valves, VCR, IGS, Block, Fittings and other key components, semiconductor equipment, special gas equipment (Gas box/VMB/VMP/VDB/VDP). Wofly owns many national patents, strictly follows the ISO9001quality system standard to execute the management, and the products have passed CE/RoHS/Semi 2 certifications. Products are widely used in Semiconductors, integrated circuits, microelectronics, LCD/LED panels,CVD/PVD, photovoltaic equipment, lithium battery equipment, hydrogen energy, laboratories, biological food engineering, medical equipment, petrochemical industry, power generation, shipbuilding and other fields. Wofly always adheres to the development concept of quality first, innovation and far-reaching, honesty and trustworthiness, attentive service, and building the future together. Customer-centric, committed to technology research and development, scientific and technological innovation, and establishing a national brand, so that customers can use safer and more assured.